| PIPE | |
|---|---|
| CAUSE | ACTION |
| 1. Pulley area over tighten | 1. Straighten the pulley plate to original condition |
| 2. Hook condition (slanting, too big, loose, etc.) | 2. Repair hook condition / change |
| 3. Modified pipe | 3. Replace to original pipe |
| HANGER PLATE ASSEMBLY | |
|---|---|
| CAUSE | ACTION |
| 1. Bolt and nut at pulley area not fully tighten | 1. Tighten the bolt and nut completely |
| 2. Ball joint not properly inserted into guide | 2. Insert the ball joint at the guide plate according to manual |
| CANOPY | |
|---|---|
| CAUSE | ACTION |
| 1. Contact to ceiling | 1. Lower the canopy at least 5mm gap from ceiling |
| BLADE | |
|---|---|
| CAUSE | ACTION |
| 1. Weight different | 1. Change new blade (all same weight) |
| 2. Pitching out (metal blade) | 2. Do pitching |
| 3. Poor installation (scr ew slanting, hook bend, screw tightening, miss screw, upside down, bend, not fully screw, etc.) | 3. Re install accor ding to manual / change, do pitching |
| 4. Modified (balancing kit, screw, etc) | 4. Re install according to manual / change, do pitching |
| BOLT & NUT | |
|---|---|
| CAUSE | ACTION |
| 1. Tightening not enough (motor to pipe area) | 1. Fully tighten the bolt & nut according to manual |
| 2. Use modified bolt and nut | 2. Replace with original bolt and nut |
| AREA | |
|---|---|
| CAUSE | ACTION |
| 1. Installation area (dome, slanting roof, room size, beam, outside windy area, etc.) | 1. Avoid these installation area condition |
| CANOPY | |
|---|---|
| CAUSE | ACTION |
| 1. Touching ceiling | 1. Lower the canopy at least 5mm gap from ceiling |
| 2. Touching motor (lower canopy) | 2. Re install the lower canopy |
| 3. Not screwed | 3. Screw the canopy completely |
| 4. Wiring arrangement inside canopy | 4. Re arrange the wiring condition inside canopy |
| 5. Installation condition (canopy step not in correct position, slanting, wrong position, etc) | 5. Correct the canopy position according to instruction manual |
| 6. Modified canopy | 6. Replace canopy with it’s original condition |
| PIPE | |
|---|---|
| CAUSE | ACTION |
| 1. Bolt and Nut not fully tighten | 1. Bolt and Nut not fully tighten |
| 2. Wrong assembly of pipe accessories | 2. Re assemble the accessories and refer to manual |
| DECO CAP, PCB COVER PLATE | |
|---|---|
| CAUSE | ACTION |
| 1. Not fully locked at the motor cover | 1. Twist the deco cap until “klik” sound heard according to instruction manual. |
| 2. Screw loose | 2. Tighten the screw |
| 3. Loose attachments | 3. Change new parts, re install according to manual |
| AREA | |
|---|---|
| CAUSE | ACTION |
| 1. Room / installation area (beam, dome, open area, slanting roof, etc) | 1. Avoid these installation area condition |
| CONNECTION | |
|---|---|
| CAUSE | ACTION |
| 1. Set connected to regulator / dimmer (remote model) | 1. Disconnect the regulator / dimmer |